How to Connect Your Generator to a Manual Transfer Switch
DIY-friendly. Code-safe. Life-safe.
Codes + local rules: Permits/inspections vary by state and municipality. Always follow your local AHJ (inspector/building department).
If you’re unsure at any point, hire a licensed electrician.
Why this matters
A manual transfer switch prevents illegal and dangerous backfeeding into the grid while allowing safe generator power to enter your home.
Never: plug a generator into a household wall outlet (“suicide cord”). That can energize utility lines and kill someone.
What you need
- Portable generator (30A or 50A split-phase if powering 240V)
- Outdoor inlet box (L14-30 or 14-50 recommended)
- Manual transfer switch installed at your main panel
- Matching generator power cord
- Gloves, eye protection, CO detector indoors
- Fire extinguisher nearby (recommended)
Step-by-step connection process
1) Generator placement
Place the generator outside, 20+ ft from openings.
2) Start the generator
Let it warm 30–60 seconds.
3) Connect the power cord
Generator → cord → inlet box.
4) Isolate from the grid
Toggle LINE → GEN on the transfer switch.
5) Power circuits one at a time
- Fridge
- Lights
- Furnace
- Sump
- Well pump
6) Monitor while running
Refuel safely and check for heat or unusual smells.
7) When grid power returns
Circuits OFF → toggle back to LINE → unplug → shutdown.
Common dangerous mistakes
- Plugging into a household wall outlet
- Running a generator in a garage (CO risk)
- Not isolating from grid power
- Turning on too many circuits at once
Quick safety gate (60 seconds)
This replaces the quiz. If any answer is “no,” don’t guess.
Stop here if anything is unclear.
Your safest next step is to confirm local requirements with your AHJ or hire a licensed electrician. If you’re considering interlocks instead, use a truly panel-matched approach: panel-matched interlock guide .
Your safest next step is to confirm local requirements with your AHJ or hire a licensed electrician. If you’re considering interlocks instead, use a truly panel-matched approach: panel-matched interlock guide .
Good path.
You’ve covered the big safety points: CO risk, isolation from the grid, load discipline, and local compliance. Next: follow manufacturer instructions and your AHJ.
You’ve covered the big safety points: CO risk, isolation from the grid, load discipline, and local compliance. Next: follow manufacturer instructions and your AHJ.
Next steps
Reminder: This guide is educational. Code requirements vary by location.